Chilled Water Systems Reports

Cooling Cost-Saving Strategies: Comfort Cooling vs. Precision Cooling
sponsored by Emerson Network Power
WHITE PAPER: Important differences exist between precision cooling and building air conditioning (comfort cooling) in controlling these environmental conditions. In this paper, we compare both cooling systems’ ability to maintain favorable environmental conditions, and their energy efficiency and annual operating costs.
Posted: 11 Oct 2010 | Published: 11 Oct 2010

Emerson Network Power

Liebert: The Right Cooling for IT Environments
sponsored by Emerson Network Power
WHITE PAPER: Many IT professionals are finding that dedicated precision cooling is the right solution to provide the ideal environment for sensitive electronics. Read this paper to learn why precision cooling is the optimal choice for keeping data centers cool in the most cost-effective way.
Posted: 13 Jul 2010 | Published: 13 Jul 2010

Emerson Network Power

Monitoring the Computer Room's Physical Environment
sponsored by Sensaphone
WHITE PAPER: This paper addresses the greatest environmental threats to the functionality of small to medium computer rooms and presents the time and cost savings associated with the integration of a remote monitoring system.
Posted: 22 Apr 2008 | Published: 22 Apr 2008

Sensaphone

Humidification Stratiegies for Data Centers and Network Rooms
sponsored by Schneider Electric
WHITE PAPER: This paper explains the nature of humidity, its effects and its management in computer rooms and data centers.
Posted: 26 Mar 2014 | Published: 20 Nov 2008

Schneider Electric

Impact of High Density Hot Aisles on IT Personnel Work Conditions
sponsored by Schneider Electric
WHITE PAPER: This white paper discusses the issue of increasing discomfort for computer room workers in high power density data centers.
Posted: 10 Oct 2013 | Published: 10 Oct 2013

Schneider Electric

Case Study: IBM Teams with Schneider Electric for Large-Scale Data Center Construction
sponsored by Schneider Electric
WHITE PAPER: Explore this concise white paper to uncover who industry leader IBM chose as their partner to undertake this challenge and how they met each goal on schedule along the way. Read on to learn which organization could keep pace with IBM to deliver the power, cooling, and single window monitoring solutions they needed.
Posted: 20 Nov 2014 | Published: 14 Nov 2012

Schneider Electric

Optimizing Capacity and Efficiency in a Diverse and Variable Load Environment
sponsored by Tate
WHITE PAPER: This whitepaper explains the need for local and dynamic airflow delivery technology and illustrates how these technologies work together with existing IT cooling systems to meet this variable load demand while maintaining high reliability and lowering energy costs.
Posted: 13 Dec 2010 | Published: 13 Dec 2010

Tate

Energy Impact of Increased Server Inlet Temperature
sponsored by Schneider Electric
WHITE PAPER: This white paper tests a commonly held idea about the optimal temperature of data center for a variety of infrastructure.
Posted: 09 Oct 2013 | Published: 06 Oct 2011

Schneider Electric

Datacenter with Energy, Temperature and Density Under Control
sponsored by Dell, Inc. and Intel®
WHITE PAPER: Check out this white paper to learn about a key case study of an organization that was able to optimize server management and energy consumption by deploying server platforms through innovative embedded capabilities.
Posted: 22 May 2013 | Published: 22 May 2013

Dell, Inc. and Intel®

The Different Technologies for Cooling Data Centers
sponsored by Schneider Electric
WHITE PAPER: This white paper talks about data center cooling and the advantages, disadvantages and applications of the 13 basic methods for heat removal.
Posted: 28 Feb 2014 | Published: 31 Dec 2012

Schneider Electric